The code here is massachusetts allows shingles on roofs with pitches of 2 12 or steeper so i m good there.
Minimum roof pitch for smart vent.
The minimum pitch for a roof is 1 4 12 which translates to 1 4 inch rise to 12 inches of run.
Asphalt shingles continue to be the most widely installed roof covering option in north america.
Wood shingles require a minimum roof pitch of 3 12 or greater.
Built up roofs require a minimum roof pitch of 1 4 12 or greater.
Mineral surfaced roll roofing requires a minimum roof pitch of 1 12 or greater.
They provide excellent weather resistance great value and now more than ever a tremendous range of beautiful designs and color blends.
Smartvent can be modified to provide intake ventilation for new roofs or re roofs through the fascia board for low slope roof with less than a 4 12 pitch.
I will install grace over the entire dormer and shingle as usual.
The short simple answer is 2 12 has traditionally been considered the absolute minimum acceptable roof slope suitable for asphalt shingles.
Click here for an expanding list of smartvent dealers.
Use the enclosed fabric at the open ends of smartvent to seal for weather.
Most houses with ridge vents do not have the proper soffit ventilation required because attic insulation blocks the soffit vents.
Smartvent allows cooler air to enter under the shingle through the 1 roof slit and out the ridge vent providing superior air flow and attic cooling.
Internal baffles drainage system and weather filter provide 3 levels of weather protection integrated end plug on both ends of vent provide a finished appearance and weather protection each vent has 9 sq.
Use smartvent tapered end caps when terminating smartvent within the shingled area of the roof.
Use of ridge or off ridge exhaust vents is required.
Of net free area per linear foot minimum 3 12 roof pitch with no maximum louver openings are sized to minimize insect infiltration and.
Slate and slate type shingles require a minimum roof pitch of 4 12 or greater.
I am planning on building a dormer that will come off the ridge with a 2 12 roof.
Look at our fasciavent which has been designed more specifically for metal roofs and provides the intake ventilation for flat to 16 12 pitches.
Smartvent should be installed on shingled roofs with a minimum 4 12 pitch.
Has anyone ever installed a ridge vent on a low slope 2 12 roof.
If you have any questions or comments on installation please call 1 800 622 4455 and ask for a roof ventilation technician to assist you.
Wood shakes require a minimum roof pitch of 3 12 or greater.