The minimum fastener pullout resistances for specific system the information listed in the chart below is for use with the referenced roof deck fastener type minimum pullout values and required penetration depths based on fasteners type.
Minimum required psi foam board for roof.
In fact the 20 2 psi value is beyond the elastic range of the eps material and long term creep effects must be taken into account when using that design approach.
Rigid foam is produced in various size panels 4 ft x 8 ft 4ft x 4ft etc.
Exceptionally high compressive strength improves overall roof system performance cement board is able to withstand prolonged exposure to moisture and is ideal for systems where wind uplift and puncture resistance are a concern.
K 360 psi 2 inches 180 pci.
Grading the isocyanurate by compressive strength grade 1 compressive strength is minimum 16 psi grade 2 is minimum 20 psi and grade 3 is minimum 25 psi.
The existing standard of 4 percent which would allow a 96 inch board to expand contract 3 13 16inches.
Meet can ulc s126 can ulc s101 and can ulc s107.
P 8000 pounds h 6 inches f c 2 500 psi e 57 000 2 500 2 850 000 psi u 0 15 k 360 psi for 1 inch eps.
Minimum slope of per foot as required by the international building code ibc toward roof.
Ul certified for canada insulated roof deck assemblies construction no.
Attach to deck board.
Plus it s light weight easy to handle and easy to cut with a knife.
Insulation requirements by climate zone.
Astm c1289 type ii class 2 grade 2 20 psi or grade 3 25 psi can ulc s704 type 2 class 3 or type 3 class 3.
Extruded polystyrene closed cell foam astm c578 type iv 25 psi minimum shipped in poly wrapped units with individually wrapped or banded bundles.
The minimum insulation requirements for ceilings walls floors and foundations in new homes as listed in the 2009 2012 2015 and 2018 iecc and irc can be found in this table additional code requirements are listed on the compliance tab of this guide.
These values are in reference to mechanically attached insulation cover boards under.
Composed of a lightweight cementicious core to provide exceptional impact resistance.
Meets the requirements of astm c 1325.
Rigid foam boards and are made.
After the roof deck is prepared the rigid foam boards need to be cut to size to fit snugly together on your roof.
Greenguard type vi 40 psi insulation board is designed for use in high load applications requiring compressive strength up to 40 psi.
The panels need to fit together tightly to help prevent warm air from leaving the top of the building.
Maximum dimensional stability limit of 2 percent vs.