Direct vent gas fireplace exhaust termination item clearance distance.
Minimum clearance on water heater roof vent.
6 minimum clearance from single wall vent pipe or flue vent connector to any combustible material.
Roof pitch rise run in inches.
Whenever we are installing a gas water heater building codes require that there should be a ventilator out of the room through the attic and out through the roof.
Single wall vents should have a minimum of 6 inches of clearance and double wall sometimes called a b vent should have 1 inch minimum clearance.
Single wall vent pipes cannot pass through a ceiling floor firewall or wall.
An exception is made for non combustible walls such as solid masonry or concrete.
Distance required usa 2.
Gas appliance direct vent clearances distances from direct gas vent to building features sidewall vent direct vent direct exhaust systems for gas fired heaters water heaters other appliances.
2 0 feet above the roof surface.
Table of rooftop chimney clearances for metal b vent chimneys flues.
Minimum height above the roof surface 1 flat to 7 12.
Number 2 is a vent for an exhaust fan like those found in bathrooms and laundry rooms.
Number 3 is a vent for an attic space called a roof vent or turtle vent.
Natural gas fireplaces gas fired furnaces boilers water heaters and wall or space heating applications.
1 5 feet above the roof surface.
If the water heater is installed above the door or window it needs 12 inches of clearance.
Type b vents ceiling floor wall clearances b vent clearances to combustibles clearance distances for a b vent to combustible materials in floors walls ceilings attics roofs.
Hot water is an essential part of everyday life.
A direct vent installation only requires a 12 inch setback from the door or window.
This article series describes b vent metal chimneys used for gas fired appliances.
Table illustrations of the required space between a direct or side wall vent for a gas fired heating appliance and building windows doors corners gas meter air intakes sidewalks balconies.
Many people can t live without a water heater.
Stack vents may give off sewer gas so they should not be located within 3 feet of an operable window.
For gas fired water heater vents.
Aluminum 012 inner wall galvanized 018 outer wall.
2 5 feet above the roof surface.
1 0 foot above the roof surface 1 7 12 to 8 12.
Distance required canada 1.
84 2 1m 3 note 5.
We discuss fire safety fire clearances and other gas appliance venting details for b vent chimneys.
Materials and construction round type b gas vent 3 8 and oval 4 6.
Note some modern high efficiency water heater may have pvc vents.
Minimum clearance distance requirements for the exterior vent termination of a gas fireplace heater 8.