No material embodied energy mj conventional roof filler slab roof quantity consumed total embodied energy mj quantity consumed total embodied energy mj 1 concrete cement kg 5 85 8453 49452 6847 40055 coarse aggregate m3 108 19 15 2068 15 51 1675 fine aggregate m3 87 5 10 837 7 76 679 2.
Filler slab roof section.
Slab thickness minimum 112 5 mm.
You can also use a general epoxy concrete filler and apply mastic on top using a trowel.
Mastic is a flexible sealant that adheres to almost any material.
Consumes less concrete and steel due to reduced weight of slab by the introduction of a less heavy low cost filler material like two layers of burnt clay tiles.
Cross section of composite slab composed of.
Filler material should be of a size and cross section.
What is filler slab filler slab is alternate slab construction technology where part of concrete in bottom of slab is replaced by filler material.
Reinforcement details clay pan positions.
If there is gravel on the roof move it aside to reach a flat surface for these kinds of applications.
The filler material to be soaked in water before casting so that it does not absorb water from concrete.
Construction detail in dwg file format.
Thus the filler slab as the roof has the following advantages.
For example grid of 35cm x 50cm is used for magalore tile as filler material and grid of 45cm x 45cm is used for clay pots of 40cm diameter filler.
Roof patch putty can be applied using a trowel to fill low areas.
View showing reinforcemnt with roof tiles in between.
Plan and section of rcc filler slab 13.
Filler material should be of good finish as the material will be in visible condition on bottom part of the slab i e.
A filler slab roof using clay pans.
Since filler roof tiles are firmly bonded to and covered by concrete.
The basic principal is that the concrete in bottom half of rcc slab is structurally not required as.
Filler materials using in a simply supported slab should be of same size and cross section without affecting the spacing of reinforcement.
Has proved the load bearing capacity of filler slab and found it no less in performance from the conventional r c c.
Typical cross section view of finished ceiling posted by sujith g s at 5 10 2011.
Cad block of composite steel deck floor.
Steel deck profiled steel sheeting steel beam or joist cast in situ concrete topping top reinforcement mesh and bottom reinforcement.
Leak proofing filler slabs.
Moreover the filler slab also provides insulation compared to a conventional rcc slab from the hot climate outside the building providing.
Share to twitter share to facebook share to pinterest.